MIL-DTL-43613E
Table II. End item visual defects.
Classification
Examine
Defect
Major
Minor
Finish
Color not as specified.
101
Exterior surface of body, cap, or strap not smooth and
not lusterless throughout (except any die parting lines).
102
Inside surface of cap, including threaded portion, not
smooth.
201
Inside surface of cap, including threaded portion, not of
uniform high luster.
202
Construction and
Component missing
103
workmanship
Any bubbles, cuts, tears, holes, flash, burns, breaks,
(applicable to all
cracks, pinholes, pits, warpage, blisters, scratches,
assemblies and
welds or sink marks, or not clean or smooth.
104
Components)
Any discoloration, surface deterioration or roughness,
foreign inclusion, or orange peel.
105
Body
Sealing surface of lip is not flat, smooth, and free from
sink marks or depressions.
106
Interior of neck opening not smooth.
107
Interior surfaces of the body not smooth.
108
Cap and strap (large
Sealing surface in cap is irregular, not smooth, or
cap or spout as
contains high or low points.
109
applicable)
Strap locking tab does not engage with tab on body
in closed position.
110
Cap does not screw on body neck or pouring spout.
111
Cap binds when screwed on body neck or pouring spout.
203
Strap does not engage in retention groove
204
Breather air vent holes not clear.
112
Threads
Threads in caps, body neck, pouring spout, or
breather stripped.
113
Threads not fully formed, not free from flash, or
misaligned at parting line.
114
Marking
Missing, incomplete, not legible, not specified type
or size, or not in proper location.
205
4.3.3.2 End item dimensional examination. The end items shall be examined for conformance to
the dimensions annotated with an asterisk on drawing 2-9-248. Only those dimensions that can
be evaluated without damaging or disassembling the end items shall be examined. Any
dimension not within the specified tolerance shall be classified as a defect. The lot size shall be
expressed in units of cans. The sample unit shall be one can. The inspection level shall be S-2
and the AQL, expressed in terms of defects per hundred units, shall be 4.0.
4.3.3.3 End item testing. The end items shall be tested as specified in 4.5.1, 4.5.2, and 4.5.3 to
detect the defects specified in table II. The lot size shall be expressed in units of cans. The
sample unit shall be can. The inspection level shall be S-3, and the AQL, expressed in terms of
defects per hundred units, shall be 2.5. Any test failure shall be cause for rejection of the lot.
6